Burdick Eclipse 850 EKG Machine
High performance and unequaled reliability in a compact package
Proven in over 10,000 installations, the Burdick Eclipse 850 EKG Machine delivers high performance in a compact package. With all the functionality of a hospital-grade ECG, it is the ideal choice for medical professionals in either a hospital or physician’s office, where ECGs are performed frequently
Burdick Eclipse 850 EKG Machine Technical Specifications:
Dimensions 11.75″ x 18.16″ x 4.14″ (299 x 462 x 105 mm)
Weight 14.2 lbs (6.45 Kg)
Display Backlit 320 x 240 LCD
Keyboard Full alphanumeric keypad
Input/output Compact flash (proprietary true IDE); Units w/communications Serial RS-232; Telephone line interface (RJ11C); Analog/TTL/ExTOL output (25 pin D)
Data storage 40 patient records
Power requirements AC operation: 115/230 V AC +/-10%, 0.80/0.40 A, 50/60 Hz; Fuses: For 115 V, 1.0A, 250 V type T; for 230 V, 0.5A 250 V type T; Battery operation: 16.8V NiCad rechargeable battery pack (80 minutes w/o printing or 40 minutes w/ 40 ECGs)
Printout Printout device: 216 mm thermal dot array; Paper dimensions: 8.5″ x 11″ (US letter) or 210 mm x 300 mm (A4); Paper type: Thermal sensitive; Chart
speeds: 10, 25, 50 mm/sec; Gain: 5, 10, 20 mm/mV; 10 mm/mV limb with 5 mm/mV chest; 20 mm/mV limb with 10 mm/mV chest; Printout formats:
Standard or cabrera 3, 4, 6 or 12 channel; additional rhythm formats
Acquisition Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6, V4R; supports Frank X, Y, Z, Cabrera, and Nehb D, A, J; Interpretation (option): Diagnosis, measurements, reason statements; Modes: Automatic, rhythm or manual; Frequency response: Meets or exceeds ANSI/AAMI EC11-1991 standard; Input impedance: Meets or exceeds ANSI/AAMI EC11-1991 standard; Electrode offset tolerance: +/-300 mV; A/D conversion: 10 µV LSB; Artifact filter response:
40 Hz, -3db; Data resolution: 500 samples/second, 5 µV
Environmental Operating temperature: 50°F to 104°F (10°C to 40°C); Operating relative specifications humidity: 25% to 95%, non-condensing; Operating atmospheric pressure: 700 KPa to 1060 KPa; Storage temperature: -4°F to 131°F (-20°C to 55°C); Storage relative humidity: 25% to 95%, non-condensing; Storage atmospheric pressure: 700 KPa to 1060 KPa
Conforms to standards EN60601-1:1999 / CSA C22.2 no. 601-1-M90 UL2601-1 EN60601-2-25 / CSA C22.2 no. 601-2-25 EN60601-1-2:1993
Safety Leakage current: Patient <10 µA, chassis <100 µA; Defibrillation protection: to 5000 V, 400J