Casmed CAS-740 Vital Signs Monitor
The Casmed CAS-740 Vital Signs Monitor offers proprietary Motion Artifact Extraction (MAXNIBP®) technology provides quick accurate blood pressure readings for neonates through adults, as well as the most challenging situations like high motion or low perfusion.
Casmed CAS-740 Vital Signs Monitor Features
- Easy-to-use, reliable, accurate
- Multi-parameter capabilities
- Fast, accurate blood pressure readings for neonates through adults
- Reduces the problems of motion in blood pressure measurement
- Monitor oximetry and temperature either continuously or in a “spot-check” mode
- Covidien FasTemp Technology gives accurate oral temperature in exactly 4 seconds
- Ideal for
- medical or surgical patients on pain medications including PCA pumps
- hospitals
- office-based endoscopy procedures
- EMS market
- Casmed’s proprietary MAXNIBP technology
- Oximetry choices include
- Masimo SET
- Nellcor OxiMax
- Nonin
- Created with emergency medical responders in mind
- Wireless Infrared printer option
- (3) Power Options
- NiMH battery pack
- internal power supply
- DC power option
- Temperature module features Fever / Hypothermic Modes
- (4) models available
- CAS 740-1: MAXNIBP
- CAS 740-2: MAXNIBP and SPO2
- CAS 740-2T: MAXNIBP and Temperature
- CAS 740-3: MAXNIBP, SPO2 and Temperature
Casmed CAS-740 Vital Signs Monitor Specifications
PHYSICAL PARAMETERS
- Dimensions: 8-1/2″ W x 3″ D x 6-3/4″ H
- Weight: 3 lbs
NIBP
- Technique: Oscillometric MAXNIBP Technology
- Patient Range: Adult – Neonate
- Measurement Range
- Systolic: 30 – 255 mmHg
- Diastolic: 15 – 220 mmHg
- MAP: 20 – 235 mmHg
- Pulse Rate Range: 30 – 240 BPM
- Accuracy
- Blood pressure: ±5 mmHg standard deviation no greater than 8 mmHg
- Pulse Rate: ±2% or ±2 BPM, whichever is greater
OPERATING MODES
- History: Review of previous measurements
- NIBP: Manual, STAT or Automatic
- %SPO2: Continuous Monitoring
- Temperature: Predictive or Direct
CONTROL PANEL
- Display: LED display of measurement results, instructions, troubleshooting messages, and signal strength bar
- Parameters Displayed: Systolic Pressure, Diastolic Pressure, Mean Arterial Pressure (MAP), Pulse Rate, %SPO2, Temperature °C / °F
PATIENT ALARMS
- Adjustable high and low alarms for Pulse Rate, SPO2, Systolic Pressure, Diastolic Pressure and Mean Arterial Pressure
POWER
- Source: External line or internal battery
- AC power: 100 – 240 VAC | 50 – 60 Hz | 0.5 A
- Fuse rating: T1.25A L250V
- DC Power: 12 – 30 VDC
- Battery: NiMH removable pack
- Charging time: 4 hours
- Operating time: minimum 4 hours of continuous operation
- Leakage current: 100 µA