GE AMX III Portable X-Ray
Introducing the next Generation of AMX mobile X-Ray system: the GE AMX III Portable X-Ray for sale. When technology fits the way you work, something inspiring happens. There’s a certain kind of pleasure you feel when highly intelligent equipment is incredibly intuitive and routine tasks are easily accomplished. Welcome to the intersection of science and empathy: GE’s mobile x-ray systems.
GE AMX III Portable X-Ray Features
- MX-75 275k HU X-ray tube with a .75mm focal spot
- LED display
- 24 kVp stations
- 28 mAs stations
- 100 mA constant
- kVp 50 –125
- mAs 0.64 – 320
GE Healthcare’s latest mobile x-ray systems are based on the revolutionary AMX family. The legacy of AMX has been proven by its more than 18,000 systems still in use. To advance something so well liked, we spent time with technologists, physicians and administrators, asking questions and observing their work habits. Through this research, we uncovered ways to help make your job easier and more productive. The result is common-sense form, intelligent function and the high image quality you demand. This is mobile x-ray taken to a new level: the GE AMX III Portable X-Ray.
GE AMX III Portable X-Ray Specifications
- Power: Obtained from rechargeable 120V battery
- Power required to recharge battery: 110 to 125 VAC | 50 – 60 Hz | 6.0 A
- Battery capacity: Approximately 10,000 mAs at 100 kVp, when fully charged
- Motor drive ratings: The drive assist unit can be driven at speeds up to 180 feet per minute or 54.9 meters per minute
- X-ray generator ratings and duty cycle: All radiographic exposures with this unit are at 100 mA
- kVp (maximum)
- 110 to 125
- 95 to 105
- 50 to 90
- mAs (maximum)
- 200
- 250
- 320
- Typical accuracy
- ±6% of kVp
- ±10% of mAs
- Conditions to meet previously mentioned accuracy
- Handswitch must have been released for 25 seconds after previous exposure.
- 15-minute interval after change completion with keyswitch in ON or CHARGE.
- Main power circuit breaker ON must be allowed before making an exposure
- Collimator Specifications
- Minimum inherent filtration is 1.5 mm aluminum equivalent to 150 kVp. Additional filtration may be obtained by inserting 1 mm and/or 2 mm aluminum filters.
- Minimum source-to-skin distance is limited to more than 30 cm by the tracks on the bottom of the collimator for mounting the accessory extension cylinder.
- Full 17” x 17” (.43 m x .43 m) radiographic coverage at 40” (1.02 m) source to image distance is provided for tubes with a 15-degree target angle.
- Collimator can be rotated and locked positively at 0º, ±15º, ±30º, ±45º, and ±90º from the front position.