Infinium Cleo Vital Signs Monitor
Introducing the Infinium Cleo Vital Signs Monitor for sale.
The Cleo is a new and intuitive approach to patient vital signs measurement. The Cleo can be configured to measure any combination of: non-invasive blood pressure, SpO2, rapid temperature, and capnography (EtCO2). Weighing in at less than 3 LBS the portable Cleo is well suited for any patient care area by offering a multitude of vital sign combinations. The Cleo can be used as a basic pulse oximeter or configured to a NIBP/SpO2/Temp spot check monitor. Cleo can also be configured to be a stand-alone capnograph or combination capnograph/SpO2/NIBP monitor. The Cleo is well suited for both bed side and mobile spot check use.
The Cleo simplifies clinician use by incorporating a touch screen with a simple user interface making the Cleo intuitive for any user. A long life lithium Ion battery is standard and many mobile mounting solutions’ are available for the Cleo.
Infinium Cleo Vital Signs Monitor Specifications
- Dimensions: 4-1/2″ W x 4″ D x 8″ H
- Weight: 2.5 lbs
- Display: 5.0 inch (Diagonal) color TFT
- Resolution: 800 × 3(RGB) × 480
- Trace: 2 Waveforms
- Waveforms: PLETH, ETCO2
- Indicators
- Alarm Indicator
- Power indicator
- Pulse beep and alarm sound
- Trend time: From 1 to 72 hours
ETCO2
- Mode of Sampling: Sidestream or Mainstream
- Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts.
- CO2 measurement Range: 0 to 150 mmHg
- CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)
- CO2 Resolution
- 0.1mmHg (0-69mmHg)
- 0.25mmHg (70-150mmHg)
- CO2 Accuracy
- 0 ~ 40 mmHg ± 2 mmHg
- 41 ~ 70 mmHg ± 5% of reading
- 71 ~ 100 mmHg ± 8% of reading
- 101 ~ 150 mmHg ± 10% of reading
- Above 80 breath per minute ± 12% of reading
- Sampling rate: 100Hz
- Respiration Rate: 2 ~ 150 bpm
- Respiration Rate accuracy: ±1 breath
- Response Time: <3 seconds – includes transport time and rise time
- Inspired CO2 measurement Range: 3 ~ 50 mmHg
- Standards: Meets performance standards of ISO/FDIS 21647:2004 (E), ASTM F1456-01, IEC/CDV 60601-2-55
NIBP
- Measuring Technology: Automatic oscillating measurement
- Cuff Inflating: < 30s (0 ~ 300 mmHg, standard adult cuff)
- Measuring Period: AVE < 40s
- Mode: Manual, Auto, STAT
- Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
- Pulse Rate Range: 30 bpm ~ 250 bpm
- Measuring Range
- Adult/Pediatric Mode SYS: 40 ~ 250 mmHg DIA: 15 ~ 200 mmHg
- Neonatal Mode SYS: 40 ~ 135 mmHg DIA: 15 ~ 100 mmHg
- Resolution: 1 mmHg
- Pressure Accuracy: Maximum Mean error: ±5 mmHg
- Maximum Standard deviation: 8 mmHg
- Overpressure Protection
- Adult Mode: 280 mmHg
- Neonatal Mode: 150 mmHg
- Alarm Limit
- SYS: 50 ~ 240 mmHg
- DIA: 15 ~ 180 mmHg
- Standards: Meets performance standards of ANSI/AAMI SP10:2002
SPO2
- ASpO2: Anti-motion SpO2
- SpO2% Range: 0 ~ 100%
- SpO2 Accuracy
- ±2% (70 ~ 100%,non-motion)
- ±3% (70 ~ 100%, motion)
- Pulse Rate Range: 30-250 bpm
- Pulse Rate Accuracy
- ±2 bpm(non-motion)
- ±3 bpm (motion)
- Alarm Limit
- Upper limit 70 ~ 100%
- Lower limit 70 ~ 100%
- SpO2 Probe
- Red light LED wavelength: 660nm±5nm
- Infrared light LED wavelength: 940nm±10nm
- Standards: Meets performance standards of EN ISO 9919:2005
TEMP
- Temperature Measurement Range: 30°C to 43°C (86°F to 109°F)
- Typical Measurement Times
- Oral (Quick Mode): 3-5 seconds (non-fever temps), 8-10 seconds (fever temps)
- Oral (Standard Mode): 6-10 seconds
- Axillary Mode: 8-12 seconds
- Rectal Mode: 10-14 seconds
- Direct Mode (All Sites): 60-120 seconds
- Pulse Timer: 60 Second count with
- 1 “beep” at 15 seconds
- 2 “beeps” at 30 seconds
- 1 “beep” at 45 seconds
- 2 “beeps”at 60 seconds
- Patient Accuracy: A Standard Prediction Mode reading and a Direct Mode reading will differ by less than ±0.2°C (±0.4°F) on 98% of tested patients
- Batteries
- (4) “AA” Required
- Standard IEC package size
- Alkaline –1.5 Volt
- Approx. 6000 temperature readings
- Standards: Meets performance standards of EN 12470-3:2000, ASTM E1112:2006
Infinium CO2
The Infinium capnography module is a field upgradeable plug-in module that allows for maximum versatility of End-tidal CO2 monitoring. Our module utilizes a low flow (50ml/min) side-stream method that allows use for intubated and non-intubated applications. Our luer lock sample line connection incorporates filter cells to eliminate the potential of cross contamination
Simple connection sample lines allows the our CO2 module to be one of the industries lowest cost per patient End-tidal CO2 systems.