Syneron eMax Laser System

$9,500.00

Quantity:
SKU: SEM-002 Categories: , Tags: , , , ,

Syneron eMax Laser System

The Syneron eMax Laser System is a complete solution for a wide range of aesthetic laser treatments, including acne, hair removal, skin rejuvenation, wrinkle reduction and much more.

Powered by Syneron’s exclusive elōs technology, which combines bi-polar radio frequency and optical energy, the Syneron eMax system is one of the most versatile cosmetic lasers you can buy. It can handle just about any aesthetic application, and it can do it with remarkable speed and patient comfort. The eMax system is easy to upgrade at any time, and unlike many other systems, it can be upgraded without the need for tools or technicians. All you need to do is simply plug in a new applicator. This model can be used on virtually any skin tone or texture and it offers an extremely large spot size of 12 mm x 15 mm for ultra fast hair removal.

Syneron eMax System Applications

  • Acne Treatment
  • Laser Hair Removal
  • Pigmented Lesions
  • Leg Veins
  • Facial Veins
  • Wrinkle Reduction
  • Fractional Laser
  • Skin Tightening
  • Skin Rejuvenation

SR/SRA Handpiece for Color Correction

The SR or SRA (for lighter skin types) applicators are intended for treatment of benign vascular and pigmented lesions. The applicators are optimized to emit light in wavelengths easily absorbed by hemoglobin and melanin. The targeted vascular or pigmented lesions absorb the light energy, raising the temperature of the target tissue. Then RF energy flows to the heated area and elevates the temperature to the level required for effective treatment and overall improved skin color.

Effect: After treatment, vascular lesions fade from sight, while pigmented lesions darken and flake away within a week or so.

ReFirme ST for Fine Wrinkle Treatment

The ReFirme ST applicator is intended for fine wrinkle treatment. Collagen and elastin depletion in the dermis result in the loss of dermal volume, creating laxity and sagging of the skin. The ST ReFirme procedure stimulates long term collagen synthesis as well as the tightening of existing collagen fibers, resulting in an immediate and long term firmed appearance. The procedure uses a combination of gentle pulsed infrared light (wavelengths 700-2000 nm) and bi-polar radio frequency (RF) to provide deep dermal heating, up to 4 mm in depth.

Effect: Initially, there is an immediate contraction of existing collagen fibers, but with time, the laxity of the brow, jowls, neck and cheek areas are expected to improve due to the collagen remodeling response.

Matrix IR for Improved Skin Texture

The Matrix IR applicator is intended for non-invasive deep wrinkle treatments. It utilizes fractional elōs technology, a combination of bi-polar radio frequency (RF) energy and diode laser energy, to penetrate into the deep dermis, down to 2.5 mm. Aging skin is characterized by collagen and elastin depletion in the dermis, resulting in loss of dermal volume, which manifests as wrinkles or sagging skin. The laser energy is delivered in a form of micro-beams creating matrix thermal bands. This fractional energy enables the introduction of more focused energy into demarcated zones in the dermis to denature and remodel collagen, leaving reservoirs of intact tissue to assist the healing process and the collagen renewal. The undamaged, but mildly heated tissue (the healing reservoirs) facilitate the healing process by serving as an activated reservoir of fibroblast cells promoting quicker healing of the damaged zones with no downtime and promoting synthesis of collagen in-situ.

Effect: Heat conducted to collagen fibers stimulates a short-term reaction of collagen contracture, followed by a long term process of new collagen remodeling, a process which is facilitated by the undamaged tissue. The Matrix IR treatment results in improved appearance of facial and neck wrinkles and rhytids.

Syneron eMax Laser Handpieces

  • ReFirme ST – Fine Wrinkle Treatment
    • RF Energy: Up to 120 J/cm³
    • Light Fluence: Up to 10 W/cm²
    • Wavelength: 700 – 2000 nm
    • Cooling: 5° – 10°C on tip
    • Spot Size: 12 mm x 8 mm
  • Matrix IR – Deep Fractional Wrinkle Treatment
    • RF Energy: Up to 100 J/cm³
    • Light Fluence: Up to 70 J/cm²
    • Wavelength: 915 nm
    • Cooling: 5°C on tip
    • Spot Size: 8 mm x 5 mm
  • SR – Skin Rejuvenation via Vascular / Pigmented Lesion Treatment
    • RF Energy: Up to 25 J/cm³
    • Light Fluence: Up to 45 J/cm²
    • Wavelength: 580 nm – 980 nm
    • Cooling: 5°C on tip
    • Spot Size: 25 mm x 12 mm
  • SRA (Advanced Skin Rejuvenation via Vascular / Pigmented Lesion Treatment
    • RF Energy: Up to 25 J/cm³
    • Light Fluence: Up to 45 J/cm²
    • Wavelength: 470 nm – 980 nm
    • Cooling: 5°C on tip
    • Spot Size: 25 mm x 12 mm
  • WRA – Wrinkle Treatment
    • RF Energy: Up to 100 J/cm³
    • Light Fluence: Up to 50 J/cm²
    • Wavelength: 915 nm
    • Cooling: 5°C on tip
    • Spot Size: 12 mm x 8 mm
  • AC – Acne Treatment
    • RF Energy: Up to 25 J/cm³
    • Light Fluence: Up to 18 J/cm²
    • Wavelength: 400 nm – 980 nm
    • Cooling: 5°C on tip
    • Spot Size: 25 mm x 12 mm
  • DS – Hair Removal
    • RF Energy: Up to 25 J/cm³
    • Light Fluence: Up to 45 J/cm²
    • Wavelength: 680 nm – 980 nm
    • Cooling: 5°C on tip
    • Spot Size:  25 mm x 12 mm
  • DSL – Laser Hair Removal
    • RF Energy: Up to 50 J/cm³
    • Light Fluence: Up to 50 J/cm²
    • Wavelength: 810 nm
    • Cooling: 5°C on tip
    • Spot Size:  15 mm x 12 mm
  • LV – Vascular Lesion Treatment
    • RF Energy: Up to 100 J/cm³
    • Light Fluence: Up to 140 J/cm²
    • Wavelength: 915 nm
    • Cooling: 5°C on tip
    • Spot Size:  8 mm x 5 mm
  • LVA – Advanced Vascular Lesion Treatment
    • RF Energy: Up to 100 J/cm³
    • Light Fluence: Up to 100 – 350 J/cm²
    • Wavelength: 915 nm
    • Cooling: 5°C on tip
    • Spot Size:  8 mm x 2 mm

The Syneron eMax Laser System Specifications

  • Exclusive elōs technology
  • Wavelength: 400 nm to 2000 nm depending on handpiece
  • Repetition Rate: Up to 2 Hz
  • Weight: 77 pounds
  • Dimensions: 18” x 17” x 40”
  • Electrical Info: Standard 110 VAC (230 VAC)

 